Tel
86-021-52970688

Supports AC and DC metering.
Provides full-wave and fundamental reactive energy; nonlinear error less than 0.1% within 5000:1 dynamic range, meeting the accuracy requirements of Class 0.5S and Class 0.2S active energy meters.
Provides full-wave and fundamental apparent energy.
Indicates active and reactive power direction and supports four-quadrant reactive power judgment.
Built-in creep start function with adjustable start threshold.
Adjustable meter constant.
Supports fast pulse counting for active, reactive and apparent energy.
Provides full-wave and fundamental pulse output for active, reactive and apparent energy.
Measures full-wave and fundamental active power, reactive power and apparent power.
Measures three-phase RMS values of full-wave, fundamental and harmonic voltage and current.
Provides full-wave and fundamental power factor.
Measures voltage line frequency with error less than 0.02%.
Measures phase angle of each phase voltage and current with error less than 0.02°.
Supports 7-channel zero-crossing detection with configurable threshold.
Detects voltage phase sequence error.
Provides voltage loss indication with configurable threshold.
Supports configurable voltage and current waveform buffer data.
Integrates voltage sag detection.
Supports overvoltage and overcurrent detection.
Supports neutral current measurement.
Low-power mode NVM2 for current comparison pre-judgment with two-level adjustable threshold; power consumption less than 150μA.
Low-power mode NVM1 for low-power current RMS measurement; power consumption less than 2mA.
Supports active reporting of total voltage loss; typical average power consumption as low as 7μA.
Built-in CT secondary open-circuit and short-circuit detection function.
Supports gain calibration for 7 ADC channels.
Supports phase calibration for 7 ADC channels; segmented phase calibration is available for Phase A, B and C current channels.
Provides power gain calibration.
Supports segmented phase calibration for active and reactive power.
Provides offset calibration for active power, reactive power and RMS values.
Equipped with checksum register for automatic verification of calibration data.
Compatible with three-phase three-wire and three-phase four-wire systems.
Single +3.3V power supply with power monitoring function.
Internal 1.25V ADC reference voltage with typical temperature coefficient of 5ppm/℃; external reference voltage is also supported.
High-speed SPI interface with transmission rate up to 3.5Mbps, with write protection function.
One interrupt output pin available.
Operating voltage range: 3.0V–3.6V.
Operating temperature range: -40℃–85℃.
Adopts eco-friendly LQFP44 package.