Tel
86-021-52970688

Supports AC and DC metering.
Provides full-wave and fundamental reactive energy; nonlinear error < 0.1% within 5000:1 dynamic range, meeting accuracy requirements of Class 0.5S and Class 0.2S active energy meters.
Provides full-wave and fundamental apparent energy.
Indicates active and reactive power direction, supports four-quadrant reactive power judgment.
Equipped with creep startup function with adjustable startup threshold.
Adjustable meter constant.
Supports fast pulse counting for active, reactive and apparent energy.
Provides full-wave / fundamental wave pulse output for active, reactive and apparent energy.
Measures full-wave and fundamental active power, reactive power and apparent power.
Measures three-phase RMS value of full-wave, fundamental and harmonic voltage and current.
Provides full-wave and fundamental power factor.
Measures voltage line frequency with measurement error less than 0.02%.
Measures phase angle of each phase voltage and current with error less than 0.02°.
Offers 7-channel zero-crossing detection with configurable zero-crossing threshold.
Detects voltage phase sequence error.
Provides voltage loss indication with configurable voltage loss threshold.
Supports flexible buffer data of voltage and current waveform.
Integrates voltage sag detection function.
Supports overvoltage and overcurrent detection.
Supports neutral current measurement.
Low-power mode NVM2 for current comparison pre-judgment with 2-level configurable threshold; power consumption less than 150μA.
Low-power mode NVM1 for low-power RMS current measurement; power consumption less than 2mA.
Supports active reporting of total voltage loss; typical average power consumption as low as 7μA.
Supports gain calibration for 7 ADC channels.
Supports phase calibration for 7 ADC channels; segmented phase calibration available for Phase A/B/C current channels.
Provides power gain calibration.
Supports segmented phase calibration for active and reactive power.
Provides offset calibration for active power, reactive power and RMS values.
Built-in checksum register for automatic verification of calibration parameters.
Compatible with three-phase three-wire and three-phase four-wire systems.
Single +3.3V power supply with built-in power monitoring function.
Internal 1.25V ADC reference voltage with typical temperature coefficient of 5ppm/℃; external reference voltage is also supported.
High-speed SPI interface with transmission rate up to 3.5Mbps, equipped with write protection function.
Equipped with one interrupt output pin.
Operating voltage range: 3.0V–3.6V.
Operating temperature range: -40℃–85℃.
Adopts eco-friendly LQFP44 package.